Read any Modbus device
in plain language

ModbusPilot turns raw registers like 08 FD into Voltage 230.1 V. Load a device profile, connect over RS-485 or TCP, and watch temperature, voltage, humidity and status update live. One small app for Windows and macOS. No cloud. No database. No sign-in.

For companies Tick the features you need — get your own custom build →
Free forever · try every paid feature for 15 minutes per launch · editions from $49 one-time · Windows & macOS · Works 100% offline
Solar invertersEnergy metersPLCsVFD drivesHVAC controllers Temperature & humidity sensorsBattery BMSFlow metersGatewaysGensets Solar invertersEnergy metersPLCsVFD drivesHVAC controllers Temperature & humidity sensorsBattery BMSFlow metersGatewaysGensets

From cable to clear values in three steps

1

Connect

Pick a COM port (RTU) or an IP address (TCP). ModbusPilot remembers it.

COM4 · 9600 8N1 · Slave 1
2

Load a profile

Drop the vendor datasheet or open a saved profile. Names, units and scales are filled in.

SUN-5K.modbuspilot.json
3

Read values

Press Start polling (F5). See words and units, not hex. Alarms light up on their own.

Grid voltage = 230.1 V
Built for hardware people

Tools that work at your bench,
not in someone else's cloud

Drop a datasheet. Get a profile.

Every vendor writes register tables differently. Smart Import reads Excel, Word, PDF, CSV or pasted text, finds the address, name, unit, scale and status texts, and builds a ready profile. You only confirm.

  • Auto column detection with a fix-it popover
  • 4xxxx, 0-based and hex addresses
  • Status codes and bit texts imported too

Poll with names, units and alarms.

The Poll Monitor reads holding, input, coil and discrete registers on a timer. Each row shows its name, scaled value and unit. Set low and high limits and the row turns red the moment a value leaves the safe range. Or switch to the Live Dashboard: big value cards with sparklines, state and bit chips, a traffic log and a decoded answer.

  • 16/32-bit, float, signed, any byte order
  • Several polls and slaves side by side
  • Grid view and per-row settings
  • Dashboard panels you can pop out, maximise, close or drag

Status codes become words.

A register that says 2 means nothing until you read page 47 of the manual. With value texts it simply says Running. Bit texts split a status word into named flags such as Grid OK or Fan fault.

Build any frame. The CRC is done for you.

The Test Center builds requests for every common function code, adds the CRC or MBAP header, sends it and decodes the answer field by field, with the reply time, a CRC check and the values by name. Perfect for firmware tests and odd devices.

Serial and SSH terminal, built in.

ModbusPilot started as a serial terminal and still is a great one: ASCII, hex and mixed send, presets, repeat, filters, framing, timestamps and logging. Switch to SSH to talk to gateways and Linux boards.

Works with scripts and AI agents.

modbuspilot-cli gives Python, PowerShell, CI pipelines and AI assistants full access to your devices: read registers, read named values from a profile, write, scan, decode and import datasheets. Clean JSON or CSV output and clear exit codes make it easy to automate.

  • Same profiles, units and value texts as the app
  • Built-in MCP server for Copilot, Claude, Cursor and other AI tools
  • Read-only for AI unless you allow writes
How to use it with your AI assistant
  1. Once per project, run modbuspilot-cli ai setup --for copilot (or claude, cursor, codex) in your project folder.
  2. Open your AI chat as usual: VS Code Copilot Chat in Agent mode, Claude Desktop, Cursor and so on.
  3. Ask in plain words, e.g. "Is the battery voltage OK?". The chat starts ModbusPilot in the background and shows each call. There is no AI window or shortcut inside ModbusPilot.

Not just a poller.
A complete bench toolkit.

Made for the people who
plug in the cables

2890 W

Solar & storage technicians

Commission inverters and batteries and read PV power, grid voltage and fault codes on site.

1532.4 kWh

Panel builders & electricians

Check energy meters and protection relays before the panel leaves the workshop.

56.5 %RH

Facility & HVAC teams

Read room sensors, chillers and air handlers without a full BMS license.

FW 2.14 OK

Device makers

Test firmware against the simulator, hammer edge cases and log every frame.