ModbusPilot Studio

Download ModbusPilot

Start with ModbusPilot Free — free forever, and every paid feature can be tried for 15 minutes each time you open it. One portable file, no installer, no admin rights, no account. When you are ready, unlock an edition from $49 one-time.

Checking available downloads…

Choose your edition

Free and all paid editions are the same download. Buying only adds a license key. The free stand-alone ModbusPilot Master and Slave tools are separate small downloads.

1

Buy once

Pick Advanced or Pro and pay once through our secure checkout. No subscription and no renewal.

2

Get your key

Your license key (it starts with MT2-) arrives by email. It names the edition or tool it unlocks.

3

Activate offline

Open Help → License / Activate (in ModbusPilot, ModbusPilot Master or ModbusPilot Slave), paste the key and press Activate. No internet needed.

Up and running in a minute

1

Save

Save ModbusPilot.exe anywhere, for example your desktop or a USB stick.

2

Run

Double-click it. If SmartScreen asks, choose More info → Run anyway (the build is not code-signed yet).

3

Poll

Open Tools → Modbus Poll Monitor (F2), pick your port and press Start polling (F5). New? Follow the first-poll guide.

System requirements

  • Windows 10 or 11, 64-bit — or macOS 11 Big Sur or newer (Apple silicon and Intel)
  • About 40 MB disk space
  • USB-RS485 / RS232 adapter for Modbus RTU, or a network for Modbus TCP
  • No internet connection needed, ever

Installing on macOS

  • Unzip ModbusPilot-macOS.zip and drag ModbusPilot.app to Applications.
  • First start: right-click the app and choose Open (the build is not notarized yet).
  • USB-RS485 adapters appear as /dev/cu.usbserial-… in the port list.
  • Free edition, evaluation, license keys and profiles work exactly like on Windows.

What's new in 1.0.0

ProfilesSmart Import wizard for Excel, Word, PDF, CSV and pasted text, plus the browser-based Profile Studio.
Live DashboardSee values as cards with units, sparklines, state and bit chips and alarm badges. Traffic and decoded-response panels can be popped out, maximised, closed or dragged; choose which values to show.
Streaming chartsTrend and value charts scroll like a recorder: old data slides out, a scrollbar reaches back through the history, and zoom shows 5 seconds up to 24 hours.
Poll MonitorMerged Modbus Master into one monitor with value texts, bit texts, alarms, grid view, trend and CSV data log.
TestingTest Center frame builder with reply time, CRC check and decoded values; device scan with radar and reply times; a Modbus slave simulator.
UsabilityCompact, expandable window, icon toolbars, stay-on-top, light and dark themes, 40 animated guides.
Command line & AINew modbuspilot-cli with JSON/CSV output and exit codes, plus a built-in MCP server so AI assistants can read your devices.
AI kitAgent Skill, Copilot custom agent, AGENTS.md section, llms.txt and modbuspilot-cli ai setup to install them for Copilot, Claude Code, Codex or Cursor.
Wake-up bytesBREAK before request can now send any hex, decimal, binary or text preamble, or nothing at all.
EditionsFree forever (terminal, Modbus master and slave simulator) plus Advanced and Pro editions; every paid feature can be evaluated for 15 minutes per launch. Portable MT2- license keys with offline activation.
Stand-alone toolsModbusPilot Master (Modbus Poll Monitor) and ModbusPilot Slave (slave simulator) are free stand-alone downloads. Both have a built-in transaction monitor.

Questions

What is free and how does the evaluation work?

ModbusPilot Free works forever: the serial and SSH terminal with presets, filters and logging, the Modbus message decoder, the Poll Monitor as a full Modbus master (RTU and TCP, several polls, writes, grid view, profiles), the slave simulator, the transaction monitor, themes and guides. Every paid feature is marked with its edition in the menus. Use one and ModbusPilot offers a 15-minute evaluation of all paid features. When the time is up, ModbusPilot asks you to buy a license or enter your key; Cancel closes ModbusPilot with all its windows and connections. The next time you open ModbusPilot you can evaluate again for 15 minutes.

Which edition do I need?

Free already covers everyday Modbus and terminal work (master over RTU and TCP, writes, several polls, profiles, slave simulator, SSH, logging). Advanced adds the test bench (Test Center, device scan, trend, Live Dashboard, CSV data log, value and bit texts, Smart Import). Pro adds command line device access, the MCP server for AI assistants and the AI kit. Need only a master or only a slave? Download the free ModbusPilot Master or ModbusPilot Slave on its own. See Compare every feature.

Is the license a subscription?

No. You pay once and the key never expires (unless it was sold as a time-limited key). All 1.x updates are included.

How do I activate my license?

Open Help → License / Activate, paste the key from your email (or load the key file) and press Activate. Activation works offline and your settings and profiles stay as they are. The same key works in ModbusPilot, ModbusPilot Master and ModbusPilot Slave. Keys of the retired Basic edition and of the former Master / Slave add-ons keep working and unlock Advanced.

Can I reset the evaluation by reinstalling?

There is nothing to reset: the Free edition never expires and the evaluation of paid features is limited per launch, not per install. The command line tool allows one 15-minute evaluation per hour.

Can I use ModbusPilot from scripts or an AI assistant?

Yes. modbuspilot-cli runs every Modbus function from the command line with JSON or CSV output, and modbuspilot-cli mcp lets GitHub Copilot, Claude, Cursor and other MCP clients read your devices. See Command line.

How do I teach my AI assistant to use ModbusPilot?

Run modbuspilot-cli ai setup --for copilot (or claude, codex, cursor) in your project to install the Agent Skill and MCP config, or give any chat the one-file guide llms-full.txt. All options are on the AI kit page.

Does ModbusPilot send any data to the internet?

No, not on its own. Everything runs on your PC. Profile Studio is a local page served from 127.0.0.1 and refuses other hosts. Data only leaves your PC when you choose to: a problem report is sent only when you press Send Report (it holds the error details, version, edition and Windows version, with user names removed from paths), and the optional AI mode of the website assistant sends your chat question to the AI service configured by the site owner.

ModbusPilot crashed or showed an error. What should I do?

When ModbusPilot hits an unexpected error or stops responding, it shows a Problem Report window: add what you were doing and press Send Report. If the cause is known you get the fix straight away. A crash that closed ModbusPilot is offered the next time it starts. You can also use Help → Report a Problem / Suggestion or the feedback page, and read our answers under Help → My Reports and Replies.

Can I ask someone about features or licensing?

Yes. Press Ask ModbusPilot at the bottom right of any page. The assistant answers questions about features, editions, prices, the evaluation and license keys from this site's documentation and links to the right guide. For orders, invoices and refunds contact support.

Which devices are supported?

Any device that speaks Modbus RTU, Modbus TCP or RTU over TCP: inverters, meters, PLCs, drives, sensors and gateways. A profile only adds names and units; you can always read raw registers.

My vendor gave me a PDF register list. Can I use it?

Yes. Drop it into Smart Import or Profile Studio. If a table is not detected, copy it as text and use Paste, or fill the CSV template.

Can I share profiles with my team?

Profiles are small JSON files. Email them, keep them in Git or on a shared drive and open them with File → Open profile.

Windows warns that the app is unknown.

The current build is not code-signed. Check the SHA-256 shown above, then choose More info → Run anyway.