ModbusPilot turns raw registers like 08 FD into Voltage 230.1 V.
Load a device profile, connect over RS-485 or TCP, and watch temperature, voltage, humidity and status update live.
One small app for Windows and macOS. No cloud. No database. No sign-in.
Pick a COM port (RTU) or an IP address (TCP). ModbusPilot remembers it.
COM4 · 9600 8N1 · Slave 1
2
Load a profile
Drop the vendor datasheet or open a saved profile. Names, units and scales are filled in.
SUN-5K.modbuspilot.json
3
Read values
Press Start polling (F5). See words and units, not hex. Alarms light up on their own.
Grid voltage = 230.1 V
Built for hardware people
Tools that work at your bench, not in someone else's cloud
Drop a datasheet. Get a profile.
Every vendor writes register tables differently. Smart Import reads Excel, Word, PDF, CSV or pasted text, finds the address, name, unit, scale and status texts, and builds a ready profile. You only confirm.
The Poll Monitor reads holding, input, coil and discrete registers on a timer. Each row shows its name, scaled value and unit. Set low and high limits and the row turns red the moment a value leaves the safe range. Or switch to the Live Dashboard: big value cards with sparklines, state and bit chips, a traffic log and a decoded answer.
16/32-bit, float, signed, any byte order
Several polls and slaves side by side
Grid view and per-row settings
Dashboard panels you can pop out, maximise, close or drag
A register that says 2 means nothing until you read page 47 of the manual. With value texts it simply says Running. Bit texts split a status word into named flags such as Grid OK or Fan fault.
The Test Center builds requests for every common function code, adds the CRC or MBAP header, sends it and decodes the answer field by field, with the reply time, a CRC check and the values by name. Perfect for firmware tests and odd devices.
ModbusPilot started as a serial terminal and still is a great one: ASCII, hex and mixed send, presets, repeat, filters, framing, timestamps and logging. Switch to SSH to talk to gateways and Linux boards.
modbuspilot-cli gives Python, PowerShell, CI pipelines and AI assistants full access to your devices: read registers, read named values from a profile, write, scan, decode and import datasheets. Clean JSON or CSV output and clear exit codes make it easy to automate.
Same profiles, units and value texts as the app
Built-in MCP server for Copilot, Claude, Cursor and other AI tools
Read-only for AI unless you allow writes
How to use it with your AI assistant
Once per project, run modbuspilot-cli ai setup --for copilot (or claude, cursor, codex) in your project folder.
Open your AI chat as usual: VS Code Copilot Chat in Agent mode, Claude Desktop, Cursor and so on.
Ask in plain words, e.g. "Is the battery voltage OK?". The chat starts ModbusPilot in the background and shows each call. There is no AI window or shortcut inside ModbusPilot.
Free forever · paid editions are one-time payments, no subscription
ModbusPilot
Everything you need to talk to field devices
A Modbus poller, a device profile importer, a test bench, a slave simulator and a serial/SSH terminal in one small offline app.
Every feature below has a short animated guide. Click Watch to see it in action.
Why one tool instead of four
Typical benches use a separate poller, a serial terminal, a protocol tester and a spreadsheet of register notes. ModbusPilot covers the daily work in one window.
modbuspilot-cli is the console twin of ModbusPilot. Read and write Modbus devices from Python, PowerShell, Bash, CI jobs
or let an AI assistant read your hardware through the built-in MCP server. Same profiles, same license, no cloud.
Put modbuspilot-cli.exe next to ModbusPilot.exe (or in your PATH); the Windows installer includes it and can add it to PATH. On macOS it is inside the zip; from source run python modbuspilot_cli.py.
1
Find the port
List serial ports with their USB adapter names.
modbuspilot-cli ports
2
Read registers
Reference addresses like 40001 work directly.
modbuspilot-cli read -p COM20 -b 115200 -a 40001 -c 18
3
Read by name
Load a profile and ask for values in plain words.
modbuspilot-cli get -p COM20 -P psu.json "Battery voltage"
Every command
Run modbuspilot-cli COMMAND --help for all options. Connection options work with every device command.
Command
What it does
Example
ports
List serial ports
modbuspilot-cli ports --json
read
Read coils, inputs or registers (FC01-04) with type, byte order and scale
modbuspilot-cli read -p COM20 -a 40036 -t uint16 --scale 0.001 --unit V
write
Write registers or coils (FC05, 06, 15, 16), echo checked
modbuspilot-cli write -p COM20 -a 40039 -v 7
poll
Read every enabled poll of a profile with names and units
Device or communication error: timeout, CRC, Modbus exception, port busy
2
Wrong usage: missing port, bad address, unknown name
3
The command needs a higher edition and the evaluation is used up
ports, decode, license and ai guide are free. Device commands, mcp and ai setup need ModbusPilot Pro;
without a Pro key they run inside a 15-minute evaluation window (one per hour). The MCP server and --watch loops stop when the window ends.
Let your AI assistant read the hardware
modbuspilot-cli mcp speaks the Model Context Protocol over stdin/stdout. Add it to your AI tool once, then ask questions like "Is the battery voltage OK?" or "Scan the bus and list all devices."
Where do I ask? In your AI chat, not in ModbusPilot.
Add ModbusPilot to your AI tool once: run modbuspilot-cli ai setup --for copilot in your project folder, or paste one of the configs below.
Restart or reload the AI tool and open its chat (VS Code: Copilot Chat, choose Agent mode; Claude Desktop: a new chat).
Ask your question. The AI tool starts modbuspilot-cli mcp by itself, calls ModbusPilot tools such as get_values and answers. Nothing to open or press in ModbusPilot.
import json, subprocess
def modbuspilot(*args):
run = subprocess.run(["modbuspilot-cli", *args, "--json"], capture_output=True, text=True)
data = json.loads(run.stdout)
if not data["ok"]:
raise RuntimeError(data["error"])
return data
values = modbuspilot("get", "-p", "COM20", "-P", "psu.json", "Battery voltage")["values"]
battery = float(values[0]["value"])
print("PASS" if 10.5 <= battery <= 12.6 else "FAIL", battery, "V")
$r = modbuspilot-cli poll -p COM20 -P psu.json --json | ConvertFrom-Json
if (-not $r.ok) { throw $r.error }
$r.values | Format-Table name, value, unit
# end-of-line test: exit code 1 means the device did not answer
modbuspilot-cli read -p COM20 -a 40001 -c 18 | Out-Null
if ($LASTEXITCODE -ne 0) { Write-Error "Board not responding" }
# log one value per second for an hour into a CSV file
modbuspilot-cli get -p /dev/ttyUSB0 -P psu.json "Battery voltage" \
--watch 1 --samples 3600 --format csv > battery.csv
# find every device on the bus
modbuspilot-cli scan -p /dev/ttyUSB0 -b 9600 --from 1 --to 247 --json | jq '.devices'
ModbusPilot comes with everything an AI assistant needs to run your Modbus bench: an Agent Skill, a custom agent,
project instructions, an MCP server and a one-file guide written for language models. Install one, then just ask
"Is the power board healthy?"
Pick the one that matches your AI tool, or combine them. All of them carry the same rules: use --json, check ok, and never write to a device without your OK.
Recommended
1
Agent Skill SKILL.md
The open Agent Skills format. The AI loads it automatically whenever you talk about Modbus, registers or your device, and reads reference.md for every detail.
For GitHub Copilot (CLI, VS Code, cloud agent, app), Claude Code, OpenAI Codex and other skill-aware agents. Put in.github/skills/modbuspilot/, .claude/skills/modbuspilot/ or .agents/skills/modbuspilot/ (personal: ~/.copilot/skills/).
The AI calls ModbusPilot tools directly: get_values, read_device, read_registers, scan_devices, get_usage_guide and more. Read-only unless you add --allow-write.
For VS Code + Copilot, Copilot CLI, Claude Desktop, Claude Code, Cursor, Codex, Windsurf and any MCP client. Get the configmodbuspilot-cli ai mcp-config --client vscode
A ready "ModbusPilot bench engineer" you pick from the agent list. It explains values in plain words, flags anything out of range and suggests the next check.
For GitHub Copilot custom agents (VS Code, CLI, github.com). Put in.github/agents/modbuspilot.agent.md
The complete manual in one plain-text file, written for language models (llms.txt standard). Upload it or paste its link, and the chat knows every command.
For ChatGPT, Claude.ai, Gemini, Copilot Chat, local LLMs, and anyone writing test scripts with AI.
An agent that can run commands teaches itself in one step. The same guide is built into the program, so it always matches the version you have.
For any terminal agent. Tell it: "Run modbuspilot-cli ai guide and use ModbusPilot." MCP clients can call get_usage_guide or read modbuspilot://guide.
Set it up in one command
Run this in your project folder. ModbusPilot writes the skill, agent, instructions and MCP config for your AI tool, merges with files you already have,
and fills in the right path to modbuspilot-cli. Add -p COM20 -b 115200 -P psu.json so the AI also knows your default device.
modbuspilot-cli ai setup --for copilot -p COM20 -b 115200 -P psu.json
created .github/skills/modbuspilot/SKILL.md Agent Skill (loads automatically)
created .github/skills/modbuspilot/reference.md full guide the skill reads on demand
created .github/agents/modbuspilot.agent.md "modbuspilot" in the agent picker
merged .vscode/mcp.json MCP server for VS Code
modbuspilot-cli ai setup --for claude -p COM20 -b 115200 -P psu.json
created .claude/skills/modbuspilot/SKILL.md
created .claude/skills/modbuspilot/reference.md
created .mcp.json project MCP server
merged CLAUDE.md short always-on section
modbuspilot-cli ai setup --for codex
created .agents/skills/modbuspilot/SKILL.md shared skills folder
created .agents/skills/modbuspilot/reference.md
merged AGENTS.md read by Codex, Cursor, Copilot, Gemini ...
- prints the [mcp_servers.modbuspilot] block for ~/.codex/config.toml
modbuspilot-cli ai setup --for cursor
merged .cursor/mcp.json MCP server for Cursor
merged AGENTS.md project rules
modbuspilot-cli ai setup --for all -p COM20 -b 115200 -P psu.json
Copilot + Claude Code + Codex + Cursor in one go. Run it again any time:
ModbusPilot replaces only its own section between the modbuspilot:begin/end markers.
modbuspilot-cli ai setup --for copilot --user
created ~/.copilot/skills/modbuspilot/SKILL.md every project, Copilot CLI and app
created ~/.copilot/agents/modbuspilot.agent.md
merged ~/.copilot/mcp-config.json Copilot CLI MCP server
modbuspilot-cli ai setup --for claude --user # ~/.claude/skills/modbuspilot
modbuspilot-cli ai mcp-config --client claude-desktop # print the config to paste
All AI commands
ai guide
Print the full guide for AI (Markdown). --brief for the short version, -o file.md to save.
ai setup
Install for copilot, claude, codex, cursor or all; --user for personal folders.
ai mcp-config
Print the MCP config for vscode, copilot-cli, claude-code, claude-desktop, cursor, codex.
ai export DIR
Write every file of the kit (skill zip included) to a folder to share with your team.
Inside the MCP server
Tool get_usage_guide: the AI learns ModbusPilot on its own
Resources modbuspilot://guide and modbuspilot://profile
Prompts health_check and explain_register for one-click questions
Write tools only with --allow-write; the port is freed after each call
The AI kit files
Plain text, no secrets, generated from the program itself so they always match the real commands. Download them here or run modbuspilot-cli ai export ./ai-kit.
File
What it is
Where it goes
modbuspilot-skill.zip
Agent Skill folder: SKILL.md + reference.md
Unzip into .github/skills/, .claude/skills/, .agents/skills/; or upload as a custom skill in Claude.ai
Start with ModbusPilot Free — free forever, and every paid feature can be tried for 15 minutes each time you open it. On Windows, choose the installer (Start menu, desktop icon, uninstaller) or the portable .exe that runs without installing. No admin rights, no account.
When you are ready, unlock an edition from $49 one-time.
Checking available downloads…
Choose your edition
Free and all paid editions are the same download. Buying only adds a license key. The free stand-alone ModbusPilot Master and Slave tools are separate small downloads.
1
Buy once
Pick Advanced or Pro and pay once through our secure checkout. No subscription and no renewal.
2
Get your key
Your license key (it starts with MT2-) arrives by email. It names the edition or tool it unlocks.
3
Activate offline
Open Help → License / Activate (in ModbusPilot, ModbusPilot Master or ModbusPilot Slave), paste the key and press Activate. No internet needed.
Up and running in a minute
1
Install or save
Run ModbusPilot-Setup.exe (no admin rights needed), or save the portable ModbusPilot.exe anywhere, for example your desktop or a USB stick.
2
Run
Open it from the Start menu or double-click the exe. If SmartScreen asks, choose More info → Run anyway (the build is not code-signed yet).
3
Poll
Open Tools → Modbus Poll Monitor (F2), pick your port and press Start polling (F5). New? Follow the first-poll guide.
System requirements
Windows 10 or 11, 64-bit — or macOS 11 Big Sur or newer (Apple silicon and Intel)
About 40 MB disk space
USB-RS485 / RS232 adapter for Modbus RTU, or a network for Modbus TCP
No internet connection needed, ever
Installing on macOS
Unzip ModbusPilot-macOS.zip and drag ModbusPilot.app to Applications.
First start: right-click the app and choose Open (the build is not notarized yet).
USB-RS485 adapters appear as /dev/cu.usbserial-… in the port list.
Free edition, evaluation, license keys and profiles work exactly like on Windows.
What's new in 1.0.0
ProfilesSmart Import wizard for Excel, Word, PDF, CSV and pasted text, plus the browser-based Profile Studio.
Live DashboardSee values as cards with units, sparklines, state and bit chips and alarm badges. Traffic and decoded-response panels can be popped out, maximised, closed or dragged; choose which values to show.
Streaming chartsTrend and value charts scroll like a recorder: old data slides out, a scrollbar reaches back through the history, and zoom shows 5 seconds up to 24 hours.
Poll MonitorMerged Modbus Master into one monitor with value texts, bit texts, alarms, grid view, trend and CSV data log.
TestingTest Center frame builder with reply time, CRC check and decoded values; device scan with radar and reply times; a Modbus slave simulator.
UsabilityCompact, expandable window, icon toolbars, stay-on-top, light and dark themes, 40 animated guides.
Command line & AINew modbuspilot-cli with JSON/CSV output and exit codes, plus a built-in MCP server so AI assistants can read your devices.
AI kitAgent Skill, Copilot custom agent, AGENTS.md section, llms.txt and modbuspilot-cli ai setup to install them for Copilot, Claude Code, Codex or Cursor.
Wake-up bytesBREAK before request can now send any hex, decimal, binary or text preamble, or nothing at all.
EditionsFree forever (terminal, Modbus master and slave simulator) plus Advanced and Pro editions; every paid feature can be evaluated for 15 minutes per launch. Portable MT2- license keys with offline activation.
Stand-alone toolsModbusPilot Master (Modbus Poll Monitor) and ModbusPilot Slave (slave simulator) are free stand-alone downloads. Both have a built-in transaction monitor.
Questions
What is free and how does the evaluation work?
ModbusPilot Free works forever: the serial and SSH terminal with presets, filters and logging, the Modbus message decoder, the Poll Monitor as a full Modbus master (RTU and TCP, several polls, writes, grid view, profiles), the slave simulator, the transaction monitor, themes and guides. Every paid feature is marked with its edition in the menus. Use one and ModbusPilot offers a 15-minute evaluation of all paid features. When the time is up, ModbusPilot asks you to buy a license or enter your key; Cancel closes ModbusPilot with all its windows and connections. The next time you open ModbusPilot you can evaluate again for 15 minutes.
Which edition do I need?
Free already covers everyday Modbus and terminal work (master over RTU and TCP, writes, several polls, profiles, slave simulator, SSH, logging). Advanced adds the test bench (Test Center, device scan, trend, Live Dashboard, CSV data log, value and bit texts, Smart Import). Pro adds command line device access, the MCP server for AI assistants and the AI kit. Need only a master or only a slave? Download the free ModbusPilot Master or ModbusPilot Slave on its own. See Compare every feature.
Is the license a subscription?
No. You pay once and the key never expires (unless it was sold as a time-limited key). All 1.x updates are included.
How do I pay and when do I get my key?
Press Buy on a paid edition. Checkout is run by Paddle, our merchant of record: pay by card, PayPal or Apple / Google Pay, with tax and invoice handled for you. As soon as the payment succeeds your MT2- license key is emailed to the address you used at checkout, usually within a minute. Nothing arrived? Check the spam folder, then email support. You have a 14-day money-back guarantee.
How do I activate my license?
Open Help → License / Activate, paste the key from your email (or load the key file) and press Activate. Activation works offline and your settings and profiles stay as they are. The same key works in ModbusPilot, ModbusPilot Master and ModbusPilot Slave. Keys of the retired Basic edition and of the former Master / Slave add-ons keep working and unlock Advanced.
Can I reset the evaluation by reinstalling?
There is nothing to reset: the Free edition never expires and the evaluation of paid features is limited per launch, not per install. The command line tool allows one 15-minute evaluation per hour.
Can I use ModbusPilot from scripts or an AI assistant?
Yes. modbuspilot-cli runs every Modbus function from the command line with JSON or CSV output, and modbuspilot-cli mcp lets GitHub Copilot, Claude, Cursor and other MCP clients read your devices. See Command line.
How do I teach my AI assistant to use ModbusPilot?
Run modbuspilot-cli ai setup --for copilot (or claude, codex, cursor) in your project to install the Agent Skill and MCP config, or give any chat the one-file guide llms-full.txt. All options are on the AI kit page.
Does ModbusPilot send any data to the internet?
No, not on its own. Everything runs on your PC. Profile Studio is a local page served from 127.0.0.1 and refuses other hosts. Data only leaves your PC when you choose to: a problem report is sent only when you press Send Report (it holds the error details, version, edition and Windows version, with user names removed from paths), and the optional AI mode of the website assistant sends your chat question to the AI service configured by the site owner.
ModbusPilot crashed or showed an error. What should I do?
When ModbusPilot hits an unexpected error or stops responding, it shows a Problem Report window: add what you were doing and press Send Report. If the cause is known you get the fix straight away. A crash that closed ModbusPilot is offered the next time it starts. You can also use Help → Report a Problem / Suggestion or the feedback page, and read our answers under Help → My Reports and Replies.
Can I ask someone about features or licensing?
Yes. Press Ask ModbusPilot at the bottom right of any page. The assistant answers questions about features, editions, prices, the evaluation and license keys from this site's documentation and links to the right guide. For orders, invoices and refunds contact support.
Which devices are supported?
Any device that speaks Modbus RTU, Modbus TCP or RTU over TCP: inverters, meters, PLCs, drives, sensors and gateways. A profile only adds names and units; you can always read raw registers.
My vendor gave me a PDF register list. Can I use it?
Yes. Drop it into Smart Import or Profile Studio. If a table is not detected, copy it as text and use Paste, or fill the CSV template.
Can I share profiles with my team?
Profiles are small JSON files. Email them, keep them in Git or on a shared drive and open them with File → Open profile.
Windows warns that the app is unknown.
The current build is not code-signed. Check the SHA-256 shown above, then choose More info → Run anyway.
Feedback & problem reports
Help us make ModbusPilot better
Report a problem, an error message or a crash, or suggest an improvement. Every report gets a ticket number. When we answer — for example “fixed in the next version” — the answer appears here and in ModbusPilot under Help → My Reports and Replies.
Known problems and fixes
When a report matches one of these causes, the answer is sent automatically.
Loading…
Custom builds for companies & teams
Your Modbus tool, with exactly your features
Tick the tools and features your team needs. We build ModbusPilot with only those features —
optionally with your company name, logo and device profiles built in — and send you an offer, usually within two working days.
Last updated 26 November 2026. Questions? Email support.
Terms of sale and license
Who sells the license
Our order process is conducted by our online reseller Paddle.com. Paddle.com is the merchant of record for all our orders: Paddle takes the payment, charges sales tax or VAT where it applies, issues your receipt or invoice and handles returns and billing questions. Paddle's buyer terms also apply to the purchase.
What you get
A one-time payment — no subscription and no renewal.
A personal license key (it starts with MT2-) emailed to the address you used at checkout, usually within a minute of a successful payment. The key contains the edition, your name and your email address.
The key never expires, unless it was sold as a time-limited key. All 1.x updates are included.
Activation works offline. The same key unlocks the paid features in ModbusPilot, ModbusPilot Master and ModbusPilot Slave.
How you may use it
One license is for one person. You may install it on every computer you use yourself, at work and at home.
Teams need one license per person who uses a paid edition; for many seats ask us for a custom offer.
Do not share, publish or resell your key, and do not try to bypass the license check. Keys that are shared publicly may be blocked in a later version.
ModbusPilot Free and the free stand-alone apps may be used at no cost, also at work.
Warranty and liability
ModbusPilot is a tool for engineers. Writing to a live device can change how machinery behaves — check addresses and values before you write, and test on a safe setup first. The software is provided “as is”. To the extent the law allows, we are not liable for indirect or consequential damage, lost data or lost production, and our total liability is limited to the price you paid. Nothing here limits rights you have under the consumer law of your country.
Privacy
The app
ModbusPilot runs on your computer and does not send anything to the internet on its own: no tracking, no analytics and no online activation. Your profiles, logs and device data stay on your PC.
A problem report is sent only when you press Send Report. It holds the error details, ModbusPilot version, edition and Windows version, with user names removed from file paths, plus the description and the email address you choose to add. Logs, profiles, device data and license keys are never included. We use reports only to fix problems and to answer you.
When you buy
Paddle.com processes your payment and billing details under its own privacy policy; we never see your card details. We receive your name, email address, country and the order details. We use them to create and email your license key, to answer support and refund requests and to keep the records the law requires. The key email is sent through our email provider, Resend. We do not sell your data and do not send newsletters.
This website
The site is hosted on Cloudflare Pages. It uses no advertising cookies; page statistics, if enabled, use Cloudflare Web Analytics, which does not use cookies. The download page asks GitHub for the newest release files. Forms (feedback, custom build) send only what you type in. The optional AI mode of the website assistant sends your chat question to the AI service configured by the site owner.
Your rights
You may ask for a copy of the data we hold about you, or ask us to correct or delete it, at any time by email. Order records we must keep for tax purposes are deleted once the legal retention period ends.
Refunds
14-day money-back guarantee. If a paid edition does not work for you, email us within 14 days of the purchase with your order number and you get a full refund — no questions asked.
Try first: every paid feature can be evaluated for 15 minutes each time you open ModbusPilot, and ModbusPilot Free works forever.
Refunds are paid by Paddle.com to the original payment method, usually within 5–10 working days.
A refunded key is no longer licensed; please stop using it and remove it from your computers.
Bought the wrong edition? We can upgrade you and charge only the difference instead.
Load datasheet
Check columns
Preview registers
Download profile
Drop a datasheet or register table here
Excel (.xlsx), CSV / TSV, Word (.docx), PDF, text, markdown or JSON — the register table is found and understood automatically.
click double-click right-click drag with the left button heldCtrl keyboard shortcut▲▼ mouse wheel
How device profiles work
A Modbus device only sends numbers. The profile tells ModbusPilot what each address means: its name, data type, scale, unit and the text for status or error codes.
Vendor datasheet Excel / Word / PDF➜Smart Import finds table + columns➜Profile .json one per device model➜ModbusPilot shows Voltage 230.1 V
Raw register 40001
0x08FD = 2301
Grid voltage 230.1 V
scale 0.1, unit V
Raw register 40005
0x0002 = 2
Run status: Fault (2)
values 0=Stop; 1=Run; 2=Fault
Raw register 40006
0x0005 = 0000 0101b
Over temp, Low voltage
bits 0=Over temp; 2=Low voltage
Raw registers 30013-30014
42 48 14 7B (Float32)
Frequency 50.02 Hz
Float32, ABCD
Make the profile once per device model, then reuse it on every site. The same ModbusPilot works with any meter, inverter, PLC or sensor — only the profile changes.
Accepted files
Source
What is read
Tip
Excel .xlsx / .xlsm
Every sheet becomes a table
Old .xls: open in Excel and Save As .xlsx
CSV, TSV, TXT, MD
Comma, semicolon, tab, | tables or space-aligned columns
Title lines above the table are skipped automatically
Word .docx
Every table; its name is the heading above it
Multi-line cells (enum lists) are kept
PDF
Tables on every page; tables continued on the next page are joined
Scanned PDFs (images) have no text — copy the table manually or use OCR first
Pasted text
Anything copied from Excel, Word, PDF viewers or web pages
Fastest way for one table in a long manual
JSON
A ModbusPilot profile (opened directly) or a list of register objects
Column names the importer understands
Columns can be in any order and use any of these names (upper/lower case and extra words are fine). Only Address is required.
Scale, Factor, Multiplier, Gain, Resolution, Ratio, Coefficient, Precision
0.1, x0.01, 1/10, /100
Unit
Unit, Units, UOM, Eng unit, Unit / Resolution
V, 0.1 V, 0.01Hz, ℃
Offset, Decimals
Value offset, Zero offset / Decimals, Decimal places, DP
-40 / 1
Value texts
Values, Enum, Options, States, Value description — or texts written inside Remarks / Description / Range
0=Stop; 1=Run; 2=Fault
Bit texts
Bits, Bit definition, Bit map, Flags — or Bit0: … texts inside Remarks
Bit0: Over temp; Bit3: Fan fault
Access
Access, R/W, Read/Write, Attribute, Permission
R, RW, Read only
Low / High
Min, Max, Lower limit, Upper limit, Alarm low / high
180 / 260
Byte order
Byte order, Word order, Endian, Swap
ABCD, CDAB, word swap, little endian, low word first
Group
Group, Category, Section, Block, Module
Measurements
No matching titles? Content is checked too: a column full of 0x00.. numbers becomes the address, U16/Float32 words become the data type and V/A/Hz/°C become units. You can always correct a choice in Column mapping.
Addresses
The datasheet shows
Meaning
Import option
40001, 30001, 10001, 00001 (5 digits) or 400001 (6 digits)
Reference numbers — the first digit is the table (4 = holding, 3 = input, 1 = discrete input, 0 = coil)
Auto detect
0x0000, 0000H, 1A
Hexadecimal protocol address
Auto, or force Hexadecimal
0, 1, 2 …
Protocol (PDU) address, starts at 0
Auto / 0-based
1, 2, 3 … but the manual says “register 1 = first register”
Register number, starts at 1
Choose 1-based
Off by one? If values look shifted by one register, switch Address base between 0-based and 1-based. 40001 and protocol address 0 are the same register.
Ranges such as 0x0010-0x0011, 16~17 or 40017..40018 define 32-bit values. Section rows such as “Input registers (FC04)” switch the function for the rows that follow.
Data types & word order
Datasheet writes
ModbusPilot type
Registers
U16, UINT, WORD, unsigned short
Unsigned
1
S16, INT16, INT, short, signed
Signed
1
U32, UINT32, DWORD, UDINT, unsigned long
UInt32
2
S32, INT32, DINT, long
Int32
2
FLOAT, FLOAT32, REAL, IEEE 754
Float32
2
U64 / S64 / DOUBLE, FLOAT64, LREAL
UInt64 / Int64 / Float64
4
STRING, ASCII, CHAR[n]
ASCII
length
HEX, BCD, BITMAP / BITFIELD
Hex / Binary
1
32/64-bit values are read in the order ABCD (big-endian) unless the table or the import option says CDAB (word swap), BADC or DCBA. If a Float32 shows nonsense like 1.2e-38, try CDAB.
Scale & units
Engineering value = raw × scale + offset. The scale may be in its own column, inside the unit (0.1V, 0.01 Hz, V/10, 1/100 kWh), or in the name (Voltage (0.1V)). Decimals are chosen from the scale automatically (0.1 → 1 decimal).
Value texts & bit texts
Value texts replace a number with a word. Bit texts name each bit of a status, alarm or error word — all set bits are shown.
Accepted writing
Shown in ModbusPilot
Values
0=Stop; 1=Run; 2=Fault 0: Stop, 1: Run 0x10 = Standby one entry per line in the same cell
raw 1 → Run (1) raw 9 → Unknown (9)
Bits
Bit0: Over temp; Bit3: Fan fault bit0=OV, bit1=UV continuation rows: “Bit 4: Grid lost” under the register row
raw 0x0009 → Over temp, Fan fault (0x0009) raw 0 → No flags (0x0000)
When writing a register that has value texts, you can type the text (Run) instead of the number.
Groups & sections
Registers are grouped into polls (one Modbus request each). Neighbouring registers are combined when the gap is ≤ Join gaps up to (default 8) and the request stays within 125 registers / 2000 bits. With One poll per group, every sheet, Word table, Group column value or section row gets its own tab. Use gap 0 for devices that reply with an exception for undocumented addresses.
Messy datasheets — checklist
Pick the right Table. All matching tables imports every register table in the file.
Check the Header row (highlighted blue in Source table).
Fix any wrong Column mapping — click a column title in the source view to assign it.
Compare two or three addresses with the datasheet (watch for off-by-one).
Read the Warnings tab: skipped rows and overlaps are listed with their line number.
Still unusual? Copy only the useful columns into the template CSV.
Build a profile library
Name files Manufacturer_Model_fwVersion.json, e.g. Acme_EM340_v2.json.
Fill Manufacturer, Model and the default connection (baud, parity, TCP port) so a technician only needs to pick the COM port.
Keep the original datasheet next to the profile; re-import when the vendor publishes a new register list.
Profiles are plain JSON — share them by e-mail, USB stick or a shared folder. No cloud needed.
How other tools do it (and what ModbusPilot takes from them)